Introduction14 configuration offers eight audio input and eight audio output channels. They all use 24-bit audio resolution.Slave Renderer — The Sla
Workflow for Hardware Setup and Application Installation 5NOTE: For an Incinerator system configuration overview, refer to the Autodesk Incinerator
Introduction16 For workflow information related to the HP xw8400 running on Linux for Incinerator, refer to the Autodesk Incinerator 2009 Installati
Hardware Configuration Guidelines 7Consult the Autodesk Web site at www.autodesk.com/lustre-documentation for the latest version of guides, release
Introduction18 Windows or Linux operating systems, HP xw8400 workstations, and peripherals associated with professional high-performance video and p
Hardware Configuration Guidelines 9The Flash® System ROM confirmation menu appears.9. Press F10 to confirm.10. Press any key.System ROM Flash was s
Introduction110 System ROM Flash was successful appears.14. Verify system BIOS settings. See “Verifying BIOS Settings” on page 10.15. From the File
Hardware Configuration Guidelines 113. Press F10 to accept the changes. 4. Select Apply Defaults and Exit. This restores the original factory syste
Introduction112 Power and Air Conditioning RequirementsThe values for power consumption and heat output were recorded on an Autodesk certified syste
Notation Conventions 13Grounding Hardware ComponentsIt is important to properly ground any audio components used with Lustre to avoid ground loops
© 2008 Autodesk, Inc. All rights reserved. Except as otherwise permitted by Autodesk, Inc., this publication, or parts thereof, may not be reproduce
Introduction114
15Connecting PeripheralsSummaryWorkflow for Connecting Peripherals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15C
Connecting Peripherals216 Connection Diagram for the HP xw8400The following diagrams show the connections for the HP xw8400 workstation. NOTE: These
Connecting the Monitor 17NOTE: The Slave Renderer option is not available for Lustre with Incinerator.Connecting the MonitorConnect the monitor to
Connecting Peripherals218 Connecting the Keyboard, Mouse, and Monitor Calibration DeviceConnect the mouse, keyboard, and monitor calibration device
Network Connections 19You can connect your workstation to two types of storage: • One or more Stone Direct disk arrays that provide storage to indi
Connecting Peripherals220 To install the Infiniband driver for use with a Windows-based Lustre workstation:1. Download the driver package to a tempo
Network Connections 215. On the Installation Options page, make sure no optional components are checked, then click Next.6. On the Select Installat
Connecting Peripherals222 8. On the Confirm Installation page, click Next to begin the installation.The wizard displays an installation progress bar
Network Connections 2318. In the Device Manager dialog box, right-click the first Infiniband port adapter.NOTE: There are two Infiniband port adapt
The following are registered trademarks or trademarks of Autodesk Canada Co. in the USA and/or Canada and other countries: Backburner,Discreet, Fire,
Connecting Peripherals224 Repeat step 19 to step 22 for the second Infiniband port adapter.The Infiniband Host Channel Adapter and the two IP over I
Network Connections 255. Configure the card so you have these values:• Receive Queue Depth of 256• Send Queue Depth of 256
Connecting Peripherals226 4-Port Broadcom AdapterConnect the workstation to your facility’s network to access background rendering nodes, other Lust
27Connecting System ComponentsSummaryWorkflow for Connecting System Components in the Lustre Workgroup . . . . 27Connecting the Autodesk Control
Connecting System Components328 Connecting the Autodesk Control SurfaceThe Autodesk control surface consists of three panels. You can use any combin
Connecting the Autodesk Control Surface 29To connect the Autodesk control surface:1. Use the AC power adapter cables to connect each panel to a pow
Connecting System Components330 If you are using only one panel, you can connect that panel directly to the workstation, instead of using the switch
Assigning an IP Address to the Autodesk Control Surface 31NOTE: The above diagrams represent a Windows-based configuration. Components may differ s
Connecting System Components332 4. Select the Use the following IP address option.5. Set a static IP and Subnet mask address for the port. Select va
Configuring Lustre to Connect to the Autodesk Control Surface 33Configuring Lustre to Connect to the Autodesk Control SurfaceAfter you have configu
Connecting System Components334 not available for the Linux-based version of Lustre, since it uses Incinerator to obtain real-time rendering and pla
Connecting the Slave Renderer to a Lustre Workstation 35Slave Render Station (HP DL140 G3)Port 1HP xw8400 Workstation(Windows-based)
Connecting System Components336 Connecting Video I/O to a Master or HD StationYou use the video components to set up video I/O and a broadcast monit
Connecting Video I/O to a Master or HD Station 37AltinexVIDEOINPUTPOWER9V 600NAOUT 1 OUT 2OUT 3 OUT 4ALTINEXDA1804NTVideo Distribution Amplifier (C
Connecting System Components338 Setting Up VTR EmulationYou can configure your Autodesk Lustre 2009 application to emulate a VTR for output in real
Connecting to a High-Speed Data Link Device (HSDL) 39Connecting to a High-Speed Data Link Device (HSDL)If you have purchased an HSDL license, you c
Connecting System Components340 Audio Wiring WorkflowThe following procedure provides the general workflow for setting up the audio subsystem for Lu
Connecting Audio Hardware 41Analog InputsAES/EBU Digital OutputsAnalog Outputs3-41-21-25-67-83-45-67-81234567812345678AES/EBU Digital Inputs RS-23
Connecting System Components342 If you have a DVS video device with an ADAT converter, to connect the Lustre hardware components to the DVS breakout
Connecting Audio Hardware 43Adjusting Lucid ADA 88192 Converter SettingsYou configure the converter through a series of setup menus that appear in
contentsvContents1 Introduction 1Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting System Components344 Menu Menu Item CommentADAT ADAT INs: SRC ONADAT INs: SMUX OFFAES AES IN1+2: SRC OFFAES IN3+4: SRC OFFAES IN5+6: SRC
index45IndexAair conditioningrequirements 12audiohardware components 40wiring workflow 40Autodesk control surfaceassigning an IP address 31configurati
46IndexKkeyboardconnecting 18LLucid ADA 88192 converter, configuring 42Lucid Converter ADA 88192 40Mmonitorconnecting 17mouseconnecting 18Nnetworkconn
tentsConviConnecting the Autodesk Control Surface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Assigning an IP Address to t
1IntroductionSummaryAbout This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction12 NOTE: If you do not have Acrobat Reader, you can download a free copy from the Adobe Web site (www.adobe.com). If you do not have Xpd
Optional Lustre Components 3Optional Lustre ComponentsYou can expand the features of your Lustre system and improve the efficiency of your workflow
Komentarze do niniejszej Instrukcji